Bộ chyển đổi Modbus TCP sang 2 cổng CAN ICP DAS ECAN-240 CR

Chia sẻ:
Mã sản phẩm: ECAN-240
Thương hiệu: ICP DAS
Tình trạng:

Modbus to 2-port CAN Bus Gateway

Liên hệ
Mô tả

Bộ chyển đổi Modbus TCP sang 2 cổng CAN ICP DAS ECAN-240 CR

Feature

  • Hardware
  • Fully compatible with the ISO 11898-2 standard
  • Built-in DIP-switch to enable/disable the terminal resistor
  • Two CAN bus interfaces with 9 pin D-sub connector
  • Two rotary switches for selection of CAN bus Baud Rate
  • Software
  • CAN bus ID filter
  • CAN bus listen only mode
  • Modbus TCP Server function
  • CAN pair connection
  • TCP/UDP to CAN transparent communication
  • Web configuration

Introduction

The IoT (Internet of Things) has been a much discussed topic in recent years. Using the IoT concept, it is easy to integrate the environment of heterogeneous network and let all of the things into be digitized making life more convenient. In order to provide additional access to IoT applications related to industry based on the CAN bus, ICPDAS has developed a new Ethernet product, the ECAN-240. 

The ECAN-240 module is a Modbus TCP to 2-port CAN Bus Gateway. As its functionality, that provides communications via the Ethernet based on the Modbus TCP industrial protocol, meaning that the module can be easily integrated with an industrial network. The ECAN-240 module includes two CAN bus interfaces, meaning that more various CAN applications can be supported.

Application

  • Factory Automation
  • Building Automation
  • Home Automation
  • Control System
  • Monitor System
  • Vehicle Automation

Modbus TCP Server:

The Modbus TCP Server function is used to implement communications between a CAN device and a Modbus TCP Client. When the ECAN-240 module is acting as a Modbus TCP Server, the Modbus TCP Client needs to use Modbus commands based on the CAN format in order to access the ECAN-240 module. The ECAN-240 module will then translate these commands into CAN format messages and send them to the CAN networks. Similarly, when a CAN format message is received from the CAN network, the ECAN-240 translates the message into Modbus format, which can then be accessed using a Modbus command.

Pair Connection:

The Pair Connection function is used to implement communication between two ends of CAN network. CAN Network #1 can communicate with CAN Network #3 or CAN Network #4 using pair connection configuration. Similarly, CAN Network #2 can also communicate with CAN Network #3 or CAN Network #4 in the same manner. The pair connection function on the ECAN-240 module is implemented via either the TCP or the UDP protocol.

TCP/UDP to CAN (transparent communication):

The Transparent option is to see as a half-pair connections. The TCP/UDP packet is in CAN format and contains the CAN ID. TCP uses port 10003 and UDP uses port 57540. This is useful because it allows custom TCP/UDP programs to be developed that can directly access the ECAN-240 module for specific applications.

Specifications

LED Indicators
Status 1 x Power
6 x CAN status
Ethernet
Ports 1 x RJ-45, 10/100Base-T(X)
Protocol Modbus TCP Server, TCP, UDP, HTTP
Socket Connections 8 for TCP, 1 for UDP
CAN
Ports 2
Baud Rate 10 k ~ 1M bps
Isolation 3000 VDC for DC-to-DC, 2500 Vrms for photo-couple
Terminal Resistor Built-in 120 ohm terminal resistor, enabled/disabled via DIP-Switch
Specification ISO 11898-2 CAN 2.0A and CAN 2.0B
Filter Yes
Power
Input Range +10 VDC ~ +30 VDC
Consumption 2 W
Mechanical
Casing Metal
Dimensions (mm) 106.8 x 146.8 x 25.9 (W x L x H)
Installation DIN-Rail
Environment
Operating Temperature -25 ~ +75 °C
Storage Temperature -30 ~ +80 °C
Humidity 10 ~ 90% RH, Non-condensing

Download

Datasheet

Documents

Ordering Information

ECAN-240     CR  Modbus TCP to 2-port CAN Bus Gateway (RoHS)