MC&TT Co., Ltd

Giới thiệu sản phẩm, giải pháp FRnet hãng ICP DAS

Chia sẻ:

FR I/O module

The FR series I/O module has an FRnet interface, which can be used as a distributed remote I/O module. The user can then easily daisy chain several FRnet modules together. FRnet modules can work with PC, PAC systems.
 

PC-based system

Since windows is a multi-tasking system, it is very difficult to implement a real-time control system, especially when most of the CPU power is consumed by image and motion cards, and the remainder is not sufficient to handle I/O control. An FRnet control board combined with FRnet I/O modules can help solve the problems faced by system designers. The FRB-200U is an FRnet communication board that can be used as a light-duty controller. For heavy-duty control applications. Refer to the literature related to the FRB-200U for more detailed information.

PC-based I/O control systems are widely used in measurement and control system applications. But sometimes it is very difficult to meet the demands of critical timing control missions. As a result of the special features of FRnet, such as real I/O synchronization and fixed scan time, FRB boards can be added to PC-based systems to give additional PLC-like control functions, with no need to mix PC-based controllers with PLCs.

Traditional high-channel-count I/O cards occupy several PC slots, and the bulky cables can be difficult to handle. Several FRB boards can be combined to work together to control thousands of I/O channels. Reduced cabling, lower labor costs, easy installation and higher reliability are the major advantages of an FRnet solution.

The FRB-200U is an isolated FRnet communication board. The FRB-200U has two FRnet ports. Each FRnet port can control a maximum of 16 communication nodes, numbered from 0 to 15. Each single node of the remote I/O module can control a maximum of 16 DI/DO (8 DI and 8 DO) channels. In other words, each FRnet port can control a maximum of 256 DI/DO (128 DI and 128 DO) channels.

Analog I/O

Model Channel Type Range Resolution Intra-module Isolation Power Consumption
Analog Input FR-2017iT  8/16 Voltage
Current
±150 mV, ±500 mV, ±1 V, ±5 V, ±10 V,
±20 mA, 0 ~ 20 mA, 4 ~ 20 mA
16-bit (1 channel)/
12-bit (8/16 channels)
3000 Vrms 2.4 W Max.
Analog Output FR-2024iT  4 Current: 0 ~ 20 mA, 4 ~ 20 mA
Voltage: 0 ~ 5V, ±5 V, 0 ~ 10 V, ±10 V
12-bit 2500 VDC 2.88 W Max.

 

Digital Input

Model FRnet Digital Input
Transfer Speed Transfer Distance Cyclic Scan Time Isolation Channel Type On Level Isolation
FR-2053T  250 K 400 m 2.88 ms - 16 Wet Contact
Sink (NPN)
20~24 VDC 1500 Vrms
FR-2053HT  1 M 100 m 0.72 ms
FR-2053TA  250 K 400 m 2.88 ms Wet Contact
Sink/Soucer
(NPN/PNP)
3.5~30 VDC 3750 Vrms
FR-2053HTA  1 M 100 m 0.72 ms
FR-2053iT  250 K/1 M 250 K: 400 m
1 M: 100 m
250 K: 2.88 ms
1 M: 0.72 ms
3000 Vrms 19~30 VDC
FR-2053iTA  3.5~30 VDC

 

Digital Output/Relay Output

Model FRnet Digital Output/Relay Output
Transfer Speed Transfer Distance Cyclic Scan Time Isolation Channel Type Load Current Isolation
FR-2057TA  250 K 400 m 2.88 ms - 16 Open Collector
Source (PNP)
100 mA 3750 Vrms
FR-2057HTA  1 M 100 m 0.72 ms
FR-2057iTA  250 K/1 M 250 K: 400 m
1 M: 100 m
250 K: 2.88 ms
1 M: 0.72 ms
3000 Vrms
FR-2057TW  - Open Collector
Sink (NPN)
250 mA
FR-2057iTW  3000 Vrms
FR-2057iT  100 mA
FR-32R/DIN 250 K 400 m 2.88 ms - 32 Power Relay From A, 3A -

 

FRnet Communication Board (PCI Bus)

Model FRnet
Ports Cyclic Scan Time Transfer Distance Transfer Speed Wire Cable
FRB-200U   2 128 input/128 output points@2.88 ms 400 m Max. 250 kbps (shielded) Twisted-pair cable
Bạn đang xem: Giới thiệu sản phẩm, giải pháp FRnet hãng ICP DAS