- Tổng tiền thanh toán:
Bộ đổi nguồn Din-Rail 220VAC sang 24VDC 100W
Khi mua hàng tại website của chúng tôi, quý khách sẽ được:
Bộ đổi nguồn Din-Rail 220VAC sang 24VDC 100W MCTT-MDR-100-24
MCTT-MDR-100 series is one economical ultra slim 100W DIN rail power supply series, adapt to be installed on TS-35/7.5 or TS-35/15 mounting rails. The body is designed 55mm in width, which allows space saving inside the cabinets. The entire series adopts the full range AC input from 85VAC to 264VAC and conforms to BS EN/EN61000-3-2, the norm the European Union regulates for harmonic current.
MCTT-MDR-100 series is designed with plastic housing that it can effectively prevent user from electric hazards. With working efficiency up to 87%, the entire series can operate at the ambient temperature between -20°C and 70°C under air convection. The complete protection functions and relevant certificates for home automations and industrial control apparatus (UL508, TUV EN60950-1, NEC class 2) make MCTT-MDR-100 a very competitive power supply solution for household and industrial applications.
Features:
Specifications
OUTPUT |
|
||
Model |
MCTT-MDR-100-12 |
MCTT-MDR-100-24 |
MCTT-MDR-100-48 |
DC Voltage |
12V |
24V |
48V |
Rated Current |
7.5A |
4A |
2A |
Current Range |
0~7.5A |
0~4A |
0~2A |
Rated Power |
90W |
96W |
96W |
Ripple & Noise |
120mVp-p |
150mVp-p |
200mVp-p |
Voltage Adj. Range |
12~15V |
24~30V |
48~56V |
Voltage Tolerance |
±1% |
±1% |
±1% |
Setup, Rise Time |
3000ms,50ms/230VAC; 3000ms,50ms/115VAC at full load |
||
Hold Up Time |
50ms/230VAC; 20ms/115VAC at full load |
||
INPUT |
|
||
Voltage Range |
88~264VAC (47~63Hz); 120~370VDC |
||
AC Current |
1.3A/115V; 0.8A/ 230V |
||
Efficiency |
83% |
86% |
87% |
Inrush Current |
Cold start, 30A at 115VAC, 60A at 230VAC |
||
Leakage Current |
<1mA/240VAC |
||
PROTECTION |
|
||
Over Load |
105%~150% |
||
Protection type: Constant current limiting, recovers automatically after fault condition is removed |
|||
Over Voltage |
125%~150% |
||
Protection type: Shut down o/p voltage, re-power on to recover |
Function |
Type |
Relay contact rating (max.): 30V/1A resistive |
Environment |
Working Temp. |
-20 ~ +70℃ (Refer to “Derating Curve”) |
Working Humidity |
20 ~ 90% RH non-condensing |
|
Storage Temp., Humidity |
-40 ~ +85℃, 10 ~ 95% RH |
|
Temp. Coefficient |
±0.03%/℃ (0 ~ 50℃) |
|
Vibration |
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
|
Safety |
Safety Standards |
UI508, TUV EN60950-1, NEC class 2 compliant |
Withstand Voltage |
I/P-O/P:3KVAC, I/P-FG:2KVAC, 1minute |
|
EMC standards |
EN55022 class B, EN61000-3-2,-3, ENV50204, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level |
|
Others |
Dimension |
55*90*100mm (L*W*H) |
Weight |
0.45Kg |
|
Connection |
I/P: 3 poles, O/P: 6 poles screw DIN terminal |
|
Note |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time. |