Bộ đổi nguồn Din-Rail 220VAC sang 24VDC 10A Leyu EDR-240-24

240W Single Output Industrial DIN Rail Power Supply EDR-240 series

Features:
Universal AC input/ full range
Built-in active PFC function
Protections: Short circuit/ Over load/ Over voltage/ Over temperature
Cooling by free air convection
Can be installed on DIN rail TS-35/7.5 or 15
LED indicator for power on
100% full load burn-in test
Fixed switching frequency at 100KHz
1  year warranty

SPECIFICATIONS

OUTPUT

 

Model

EDR-240-24

EDR-240-48

DC Voltage

24V

48V

Rated Current

10A

5A

Current Range

0-10A

0-5A

Rated Power

240W

240W

Ripple & Noise

150mVp-p

360mVp-p

Voltage Adj. Range

21-28V

43-53V

Voltage Tolerance

±1%

±1%

Setup, Rise Time

800ms,40ms/230VAC   800ms,40ms/115VAC at full load

Hold Up Time

24ms/230VAC   24ms/115VAC at full load

 

 

INPUT

 

Voltage Range

176~264VAC   47~63Hz; 240~370VDC

AC Current

2.8A/115V   1.4A/230V

Efficiency

84%

85%

Inrush Current

Cold start 27A/115V   45A/230V

Leakage Current

<3.5mA/240VAC

 

 

PROTECTION

 

Over Load

105%~150%

Protection type: Constant current limiting, recovers automatically after fault condition is removed

Over Voltage

30-36V

54-60V

Protection type: Shut down o/p voltage, re-power on to recover

Over Temp.

100℃±5℃(TSW1)

Protection type: Shut down o/p voltage, recovers automatically after temperature goes down

 

 

ENVIRONMENT

 

Working Temp., Humidity

-10℃~+70℃; 20%~90%RH

Storage Temp., Humidity

-20℃~+85℃; 10%~95%RH

Vibration

10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axes

 

 

SAFETY

 

Withstand Voltage

I/P-O/P: 3KVAC   I/P-FG: 1.5KVAC   O/P-FG: 0.5KVAC

Isolation Resistance

I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC

 

 

STANDARD

 

Safety Standard

Design refer to UL508,UL60950-1, TUV EN60950-1

EMC Standard

EN55011,EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11,ENV50204,EN55024,EN61000-6-2(EN50082-2)

 

 

OTHERS

 

Dimension

63*125.2*115mm(L*W*H)

Weight

0.85Kg

Packing

20pcs/17.5Kg/1.2CUFT

 

 

NOTE

 

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1μ & 47μ parallel capacitor.

3 .Tolerance: includes set up tolerance, line regulation and load regulation.

4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.

5 . Derating may be needed under low input voltages. Please check the derating curve for more details.

Đăng nhập