- Tổng tiền thanh toán:
RK500-12 Liquid PH Sensor Water Quality Monitoring Sensor
Khi mua hàng tại website của chúng tôi, quý khách sẽ được:
Cảm biến đo độ pH chất lỏng Rika RK500-12
PRODUCT DESCRIPTION
RKk500-12 PH sensor is a good solution to measure the PH value. It does not require a professional calibration instrumentand is simple to operate. lt can be used to continuously measure the PH value of wastewater . It is suitable for agriculture,sewage treatment plants, chemical industry, printing and dyeing, papermaking, pharmaceuticals. , electroplating and environmental protection.
SPECIFICATIONS
Item |
Technical Specification |
Measurement Principle |
Electrochemistry |
Range |
0-14PH |
Supply |
7-30VDC(power consumption<0.2W) |
Accuracy |
±0.05PH |
Resolution |
0.01PH |
Temperature Compensation |
Temperature compensation is optional |
Response time |
<8s(flowing liquid), <14s(stationary liquid) |
Stability |
≤0.01PH/24h |
Output Signal |
4-20mA & RS485 at the same time |
Calibration Cycle |
Every 6 month(General water ) |
Operating Environment |
0-+80℃(<0.6MPa), high pressure is customizable |
Cable length |
5m(default),customizable |
Ingress Protection |
IP68 |
Storage |
10-60℃@20%-90%RH |
PH SCALE |
|||
PH value |
Description |
PH value |
Description |
<4.5 |
Strongly acidity |
7.5-8.5 |
Faintly alkalinity |
4.5-5.5 |
Acidity |
8.5-9.5 |
Alkalinity |
5.5-6.5 |
Faintly acidity |
>9.5 |
Strongly alkalinity |
6.5-7.5 |
Neutral |
|
DIMENSION
Type A
Universal type ABS housing, Up and down are NPT3/4 threads
Type B
Highly corrosion resistant PPS housing, Up and down are NPT3/4 threads
Type C
Standard glass type Length=120mm
Unit:mm
ELECTRODE MAINTENANCE & INSTALLATION AND FIXED
PH electrode is not used at ordinary times and can be soaked in 3mol/l KCL solution or saturated KCL solution. It is strictly prohibited to immerse the electrode in distilled water and deionize the water or tap water with minimal plasma content.If the PH electrode is contaminated with inorganic substances, it can be cleaned with 0.1mol/l Hcl or NaOH solution for a few minutes and then washed with distilled water. If the PH electrode is contaminated with organic substances, it can be cleaned with alcohol or acetone and then cleaned with distilled water.(note: the protective cap before the electrode should be removed when using);
Clean the electrode with tap water every 3 months or 6 months according to the working environment.
Mounting bracket(length=1m) is optional
PRODUCT DETAILS
Product Principle
Water-Proof