Bộ đổi nguồn tổ ong 220VAC sang 12VDC 3A Leyu MS-35-12

35W Single Output Switching Power Supply MS-35 series

Low price and high reliability

105℃ output capacitor

AC input power suitable for the world

Hight efficiency and low operation temperature

Soft-start current can reduce the AC input impact effectively

With Short-circuit and overload protection

Compact size,light weight

100% full-load burning test

Installed with EMI filter, minimum wave

SPECIFICATIONS
OUTPUT  
Model

MS-35-5

MS-35-12

MS-35-24

DC Voltage

5V

12V

24V

Rated Current

7A

3A

1.4A

Current Range

0-3A

0-3A

0-1.4A

Rated Power

35W

36W

33.6W

Ripple & Noise

50mVp-p

50mVp-p

100mVp-p

Voltage Adj. Range

+10,-5%

±10%

±10%

Voltage Tolerance

±2%

±1%

±1%

Inlet Stability

±0.5%

±0.5%

±0.5%

Load Stability

±1%

±0.5%

±0.5%

Setup, Rise, Hold Up Time 200s,100ms,30ms at full load
INPUT  
Voltage Range 100~240VAC   47-63Hz; 240~370VDC
AC Current 0.5A/115V   0.25A/230V
Efficiency

65%

68%

72%

Inrush Current Cold-start current 15A/115V   30A/230V
Leakage Current <0.5mA/240VAC
PROTECTION  
Over Load 105%~150%
Protection type: Fold back current limiting Reset: auto recovery
ENVIRONMENT  
Working Temp., Humidity -10℃~+60℃(Refer to output derating curve), 20%~90%RH
Storage Temp., Humidity -20℃~+85℃,10%~95%RH
Temp. Coefficient ±0.02%/℃(0~50%)
Vibration 10~500Hz,2G 10min,/1cycle,Period for 60min,each axes
SAFETY  
Withstand Voltage I/P-O/P: 1.5KVAC   I/P-FG: 1.5KVAC   O/P-FG: 0.5KVAC
Isolation Resistance I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC
STANDARD  
Safety Standard Meet UL1012 requirement(Not apply for the mark)
EMC Standard Meet FCC PART15 J Conduction class B
OTHERS  
Dimension 85*58*38mm(L*W*H)
Weight 0.4Kg
NOTE  
1.The testing condition for the parameter above is: 230VAC input, rated load, 25℃ 70% RH.Humidity.

 

2.Error.include the setting error,line stability and load stability.

3.Wave test:adopting “A12”double wire for 20MHz,and 0.1UF&47UF capacitor short-circuit for interrupting.

4.Inlet voltage stability test:when is over load,the lowest voltage of inlet is up to the highest voltage.

5.Load stability test:the load is from 0% to 100%.