Bộ đổi nguồn Din-Rail MCTT-NDR-480-24 480W, 24VDC, 20A

Chia sẻ:
Mã sản phẩm: MCTT-NDR-480-24
Thương hiệu: MCTT
Tình trạng:

Bộ đổi nguồn Din-Rail MCTT-NDR-480-24 480W, 24VDC, 20A

Liên hệ
Mô tả

Bộ đổi nguồn Din-Rail MCTT-NDR-480-24 480W, 24VDC, 20A

MCTT-NDR-480 series is one economical slim 480W DIN rail power supply series, adapt to be installed on TS-35/7.5 or TS-35/15 mounting rails. The body is designed 85.5mm in width, which allows space saving inside the cabinets. The entire series adopts the full range AC input from 176VAC to 264VAC and conforms to BS EN/EN61000-3-2, the norm the European Union regulates for harmonic current.

In MCTT-NDR-480 is designed with metal housing that enhances the unit’s power dissipation. With working efficiency up to 85%, the product can operate at the ambient temperature between -10°C and 70°C under air convection. It is equipped with constant current mode for over-load protection, fitting various inductive or capacitive applications. The complete protection functions and relevant certificates for industrial control apparatus (UL508, TUV EN60950-1, and etc.) make MDC480 a very competitive power supply solution for industrial applications.

Tính năng

  • Universal AC input/ Full range
  • Built-in active PFC function
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Cooling by free air convection
  • UL508 approved
  • LED indicator for power on
  • Can be installed on Din-rail TS-35/7.5 or 15
  • 100% full load burn-in test
  • Fixed switching frequency at 100KHz

Thông số kỹ thuật

SPECIFICATIONS

OUTPUT

 

Model

MCTT-NDR-480-24

MCTT-NDR-480-48

DC Voltage

24V

48V

Rated Current

20A

10A

Current Range

0-20A

0-10A

Rated Power

480W

480W

Ripple & Noise

240mVp-p

480mVp-p

Voltage Adj. Range

21-28V

43-53V

Voltage Tolerance

±1%

±1%

Setup, Rise Time

1200ms,40ms/230VAC   800ms,40ms/115VAC at full load

Hold Up Time

24ms/230VAC   24ms/115VAC at full load

 

 

INPUT

 

Voltage Range

176~264VAC   47~63Hz; 240~370VDC

AC Current

2.8A/115V   1.4A/230V

Efficiency

84%

85%

Inrush Current

Cold start 27A/115V   45A/230V

Leakage Current

<3.5mA/240VAC

 

 

PROTECTION

 

Over Load

105%~150%

Protection type: Constant current limiting, recovers automatically after fault condition is removed

Over Voltage

30-36V

54-60V

Protection type: Shut down o/p voltage, re-power on to recover

Over Temp.

100℃±5℃(TSW1)

Protection type: Shut down o/p voltage, recovers automatically after temperature goes down

 

 

ENVIRONMENT

 

Working Temp., Humidity

-10℃~+70℃; 20%~90%RH

Storage Temp., Humidity

-20℃~+85℃; 10%~95%RH

Vibration

10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axes

 

 

SAFETY

 

Withstand Voltage

I/P-O/P: 3KVAC   I/P-FG: 1.5KVAC   O/P-FG: 0.5KVAC

Isolation Resistance

I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC

 

 

STANDARD

 

EMC Standard

EN55011,EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11,ENV50204,EN55024,EN61000-6-2(EN50082-2)

 

 

OTHERS

 

Dimension

125.5*125.2*100mm(L*W*H)

Weight

1.3Kg

Packing

12pcs/15.5Kg/1.2CUFT

 

 

NOTE

 

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1μ & 47μ parallel capacitor.

3 .Tolerance: includes set up tolerance, line regulation and load regulation.

4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.

5 . Derating may be needed under low input voltages. Please check the derating curve for more details.

Tài liệu