Get reliable power with our 200W Single Output Switching Power Supply from the LRS-200 series. As a factory, we guarantee top-quality performance.
Khi mua hàng tại website của chúng tôi, quý khách sẽ được:
Bộ đổi nguồn tổ ong MCTT-LRS-200-24 200W, 24VDC, 8.3A
MCTT-LRS-200 series is a 200W single output enclosed type power supply with 30mm of low profile design. Adopting the input of 115VAC or 230VAC (select by switch), the entire series provides an output voltage line of 5V, 12V, 24V, 36V and 48V.
In addition to the high efficiency up to 90%, the design of metallic mesh case enhances the heat dissipation of MCTT-LRS-200 that the whole series operates from -25 ~ 70℃ under air convection without a fan. Delivering an extremely low no load power consumption (less than 0.75W), it allows the end system to easily meet the worldwide energy requirement. MCTT-LRS-200 has the complete protection functions and 5G anti-vibration capability; it is complied with the international safety regulations such as UL60950-1. MCTT-LRS-200 series serves as a high price-to-performance power supply solution for various industrial applications.
Features:
Specifications
SPECIFICATION | |||||||
OUTPUT | |||||||
Model | MCTT-LRS-200-3.3 | MCTT-LRS-200-5 | MCTT-LRS-200-12 | MCTT-LRS-200-15 | MCTT-LRS-200-24 | MCTT-LRS-200-36 | MCTT-LRS-200-48 |
DC Voltage | 3.3V | 5V | 12V | 15V | 24V | 36V | 48V |
Rated Current | 40A | 40A | 17A | 14A | 8.8A | 5.9A | 4.4A |
Current Range | 0~40A | 0~40A | 0~17A | 0~14A | 0~8.8A | 0~5.9A | 0~4.4A |
Rated Power | 132W | 200W | 204W | 210W | 211.2W | 212.4W | 211.2W |
Ripple & Noise | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | 200mVp-p |
Voltage Adj. Range | 2.97~3.6V | 4.5 ~ 5.5V | 10.2~ 13.8V | 13.5~18V | 21.6~28.8V | 32.4~39.6V | 43.2~52.8V |
Voltage Tolerance | ±3.0% | ±3.0% | ±1.5% | ±1.0% | ±1.0% | ±1.0% | ±1.0% |
Line Regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Load Regulation | ±2.5% | ±2.0% | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Setup, Rise Time | 1300ms, 50ms/230VAC 1300ms, 50ms/115VAC at full load | ||||||
Hold Up Time | 16ms/230VAC 12ms/115VAC at full load | ||||||
INPUT | |||||||
Voltage Range | 90 ~ 132VAC / 180 ~ 264VAC selected by switch 254 ~ 370VDC (switch on 230VAC) | ||||||
Frequency Range | 47 ~ 63Hz | ||||||
Efficiency | 87% | 88% | 89.50% | 89.50% | 90% | ||
AC Current | 4A/115VAC 2.2A/230VAC | ||||||
Inrush Current | Cold start 60A/115VAC 60A/230VAC | ||||||
Leakage Current | <2mA / 240VAC | ||||||
PROTECTION | |||||||
Over Load | 110 ~ 140% rated output power | ||||||
Protection type: Hiccup mode, recovers automatically after fault condition is removed | |||||||
Over Voltage | 5.75~6.75V | 13.8 ~ 16.2V | 18~21V | 28.8 ~ 33.6V | 41.4~46.8V | 55.2~ 64.8V | |
Protection type: Hiccup mode, recovers automatically after fault condition is removed | |||||||
Over temperature | Hiccup mode, recovers automatically after fault condition is removed | ||||||
ENVIRONMENT | |||||||
Working Temp. | -25 ~ +70℃ (Refer to “derating curve”) | ||||||
Working Humidity | 20 ~ 90% RH non-condensing | ||||||
Storage Temp., Humidity | -40 ~ +85℃, 10 ~ 95% RH | ||||||
Temp. Coefficient | ±0.03%/℃ (0 ~ 50℃) | ||||||
Vibration | 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes | ||||||
SAFETY | |||||||
Safety Standards | UL60950-1 approved | ||||||
Withstand Voltage | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | ||||||
Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃ / 70% RH | ||||||
OTHERS | |||||||
Dimension | 215*115*30mm (L*W*H) | ||||||
Weight | 0.66Kg | ||||||
Packing | 15pcs/carton/10.9kg/0.78CUFT | ||||||
NOTE | |||||||
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time. |