Mô tả

Bộ đổi nguồn tổ ong 220VAC sang 12VDC, 100W, 8.5A MCTT-LRS-100-12

MCTT-LRS-100 series is a 100W single output enclosed type power supply with 30mm of low profile design. Adopting the full range 85~264VAC input, the entire series provides an output voltage line of 5V, 12V, 24V, 36V and 48V.

In addition to the high efficiency up to 91%, the design of metallic mesh case enhances the heat dissipation of MCTT-LRS-100 that the whole series operates from -30 ~ 70℃ under air convection without a fan. Delivering an extremely low no load power consumption (less than 0.3W), it allows the end system to easily meet the worldwide energy requirement. MCTT-LRS-100 has the complete protection functions and 5G anti-vibration capability; it is complied with the international safety regulations such as UL60950-1, IEC/EN60950-1, IEC/EN61558-2-16, IEC/EN60335-1 and CCC GB4943. MCTT-LRS-100 series serves as a high price-to-performance power supply solution for various industrial applications.

Features:

  • Universal AC input/ Full range
  • Withstand 300VAC surge input for 5 second
  • Protections: Short circuit / Overload / Over voltage
  • Cooling by free air convection
  • Miniature size and 1U low profile
  • LED indicator for power on
  • 100% full load burn-in test
  • High operating temperature up to 70℃
  • High efficiency, long life and high reliability
  • 1 years warranty

Specifications

Model

MCTT-LRS-100-5

MCTT-LRS-100-12

MCTT-LRS-100-24

MCTT-LRS-100-36

MCTT-LRS-100-48

 

 

 

 

 

 

 

 

 

 

 

 

Output

DC Voltage

5V

12V

24V

36V

48V

Rated Current

18A

8.5A

4.5A

2.8A

2.3A

Current Range

0~18A

0~8.5A

0~4.5A

0~2.8A

0~2.3A

Rated Power

90W

102W

108W

100.8W

110.4W

Ripple & Noise

100mVp-p

120mVp-p

150mVp-p

200mVp-p

200mVp-p

Voltage Adj. Range

4.5~5.5V

10~ 13.8V

21.6~28.8V

32~39.6V

43.2~52.8V

Voltage Tolerance

±2%

±1%

±1%

±1%

±1%

Line Regulation

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

Load Regulation

±1%

±0.5%

±0.5%

±0.5%

±0.5%

Setup, Rise Time

500ms, 30ms/230VAC            500ms, 30ms/115VAC at full load

Hold Up Time

55ms/230VAC           10ms/115VAC at full load

 

 

 

 

 

 

Input

Voltage Range

85 ~ 264VAC            120~373VDC

Frequency Range

47 ~ 63Hz

Efficiency

86%

88%

90%

90.5%

91%

AC Current

1.9A/115VAC  1.2A/230VAC

Inrush Current

Cold start, 50A at 230VAC

Leakage Current

<0.75mA / 240VAC

 

 

 

 

Protection

Over Load

110 ~ 150% rated output power

Protection type: Hiccup mode, recovers automatically after fault condition is removed

Over Voltage

115%~135% rated output voltage

Protection type: Shut down and latch off o/p voltage, re-power on to recover

 

 

 

 

 

 

Environment

Working Temp.

-30 ~ +70℃ (Refer to “Derating Curve”)

Working Humidity

20 ~ 90% RH non-condensing

Storage Temp., Humidity

-40 ~ +85℃, 10 ~ 95% RH

Temp. Coefficient

±0.03%/℃ (0 ~ 50℃)

Vibration

10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes

 

 

Safety

Safety Standards

UL60950-1, IEC/EN60950-1, IEC/EN61558-2-16, IEC/EN60335-1, CCC GB4943 approved

Withstand Voltage

I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC,1minute

EMC standards

EN55022 class B, EN55014, EN61000-3-2,3, EN61000-4,2,3,4,5,6,8,11, GB9254

 

 

Others

Dimension

129*97*30mm (L*W*H)

Weight

0.34Kg

Connection

7P/9.5mm pitch terminal block

Note

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance: includes set up tolerance, line regulation and load regulation.

4. Line regulation is measured from low line to high line at rated load.

5. Load regulation is measured from 0% to 100% rated load.

6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.

7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.

Datasheet