-
- Tổng tiền thanh toán:
Get the 100W Single Output Switching Power Supply from our factory. LRS-100 series offers reliable and efficient power solutions. Trust our quality and expertise.
Khi mua hàng tại website của chúng tôi, quý khách sẽ được:
Bộ đổi nguồn tổ ong MCTT-LRS-100-12 100W, 12VDC, 8.5A
MCTT-LRS-100 series is a 100W single output enclosed type power supply with 30mm of low profile design. Adopting the full range 85~264VAC input, the entire series provides an output voltage line of 5V, 12V, 24V, 36V and 48V.
In addition to the high efficiency up to 91%, the design of metallic mesh case enhances the heat dissipation of MCTT-LRS-100 that the whole series operates from -30 ~ 70℃ under air convection without a fan. Delivering an extremely low no load power consumption (less than 0.3W), it allows the end system to easily meet the worldwide energy requirement. MCTT-LRS-100 has the complete protection functions and 5G anti-vibration capability; it is complied with the international safety regulations such as UL60950-1, IEC/EN60950-1, IEC/EN61558-2-16, IEC/EN60335-1 and CCC GB4943. MCTT-LRS-100 series serves as a high price-to-performance power supply solution for various industrial applications.
Features:
Specifications
Model |
MCTT-LRS-100-5 |
MCTT-LRS-100-12 |
MCTT-LRS-100-24 |
MCTT-LRS-100-36 |
MCTT-LRS-100-48 |
|
Output |
DC Voltage |
5V |
12V |
24V |
36V |
48V |
Rated Current |
18A |
8.5A |
4.5A |
2.8A |
2.3A |
|
Current Range |
0~18A |
0~8.5A |
0~4.5A |
0~2.8A |
0~2.3A |
|
Rated Power |
90W |
102W |
108W |
100.8W |
110.4W |
|
Ripple & Noise |
100mVp-p |
120mVp-p |
150mVp-p |
200mVp-p |
200mVp-p |
|
Voltage Adj. Range |
4.5~5.5V |
10~ 13.8V |
21.6~28.8V |
32~39.6V |
43.2~52.8V |
|
Voltage Tolerance |
±2% |
±1% |
±1% |
±1% |
±1% |
|
Line Regulation |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
|
Load Regulation |
±1% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
|
Setup, Rise Time |
500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load |
|||||
Hold Up Time |
55ms/230VAC 10ms/115VAC at full load |
|||||
Input |
Voltage Range |
85 ~ 264VAC 120~373VDC |
||||
Frequency Range |
47 ~ 63Hz |
|||||
Efficiency |
86% |
88% |
90% |
90.5% |
91% |
|
AC Current |
1.9A/115VAC 1.2A/230VAC |
|||||
Inrush Current |
Cold start, 50A at 230VAC |
|||||
Leakage Current |
<0.75mA / 240VAC |
|||||
Protection |
Over Load |
110 ~ 150% rated output power |
||||
Protection type: Hiccup mode, recovers automatically after fault condition is removed |
||||||
Over Voltage |
115%~135% rated output voltage |
|||||
Protection type: Shut down and latch off o/p voltage, re-power on to recover |
Environment |
Working Temp. |
-30 ~ +70℃ (Refer to “Derating Curve”) |
Working Humidity |
20 ~ 90% RH non-condensing |
|
Storage Temp., Humidity |
-40 ~ +85℃, 10 ~ 95% RH |
|
Temp. Coefficient |
±0.03%/℃ (0 ~ 50℃) |
|
Vibration |
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes |
|
Safety |
Safety Standards |
UL60950-1, IEC/EN60950-1, IEC/EN61558-2-16, IEC/EN60335-1, CCC GB4943 approved |
Withstand Voltage |
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC,1minute |
|
EMC standards |
EN55022 class B, EN55014, EN61000-3-2,3, EN61000-4,2,3,4,5,6,8,11, GB9254 |
|
Others |
Dimension |
129*97*30mm (L*W*H) |
Weight |
0.34Kg |
|
Connection |
7P/9.5mm pitch terminal block |
|
Note |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time. |